DESCRIPTION
The INVALCO Model 700 Batch Controller is designed to interface with all INVALCO turbine meters and a wide range of flow measurement devices produced by other manufacturers.
Specifications
| Display | Six digit LCD, 0.7” high digits. |
| Keyboard | Sealed membrane keyboard with four keys. |
| Transducer Supply | 8-24 Vdc field adjustable, 50mA maximum (2-3V less than minimum input voltage) |
| Power Requirements | 11.5 to 28.0 Vdc, 140mA typical (no options). AC Mains: Set internally to 95-135 Vac or 190-260 Vac. |
| Operating Temperature | 32°F to 130°F (0°C to 55°C). |
| Facia | Watertight to NEMA 3S or IP65. |
| Dimensions | 5.7” (144mm) wide x 2.8” (72mm) high x 7.4” (188mm) deep. |
| Panel Cutout | 5.5” (139mm) x 2.6” (67mm). |
| Frequency Input Frequency Range: Input Circuits: K-Factor Range: Non-Linear Correction: |
Minimum - 0.25 Hz on rate. 0 Hz on total. Maximum - 10 kHz. Will accept most sine, logic, and proximity switch inputs. 0.1000 to 50,000. Up to ten correction points. |
| Scaled Pulse Output Pulse Width: Duty Cycle: Output: |
10 mSec (negative going pulse). Maximum of 49 pulses per second. An open-collector transistor will sink 100 mA maximum. The pulse output is suitable for driving remote counter or PLCʼs. |
| 4-20mA Input Option (700LA Only) Input: Input Impedance: Accuracy: Circuit: |
For density or temperature. 250 ohms. 0.05%. The 250 ohm resistors are connected to a common signal ground (current sinking). |
| RTD Input Option (700 LR) Temperature Measurement Range: Accuracy: RTD Type: Linearity: |
-148°F to 392°F (-100°C to 200°C) Note: A wider temperature range can be handled via a 4-20mA input. 0.1°C Platinum PT100, two, three, or four-wire The non-linearity of the RTD is internally compensated for. |
| RS232/422/485 Option Type: Function: Printer: Computer: Baud Rate: Data Bits: Parity: Time: |
RS232, four wire RS422 and two wire RS485 are provided. When using the RS422/485, multipoint communication can be implemented with up to 32 instruments connected to a common bus. Printer and computer protocols are A print is initiated on each reset or at a programmable time interval. Protocols are provided for roll and column printers An ASCII-based protocol enables all displayed 300 to 9,600 Seven or eight Non, odd, or even A real-time clock is provided to give time and date on each output. |
| 4-20mA Output Option Function: Resolution: Accuracy: Maximum Load: Isolation: |
Via 4mA and 20mA, fully scaled and programmable. Ten bits. Better than 0.1%. Voltage Burden: 5V;500 ohms internally powered;950 ohms from external 24 Vdc. Output is isolated. |
| Relay Output Option (Valve Control) Function: Maximum Switching Power: Maximum Switching Voltage: Maximum Switching Current: |
One or two stage valve control is provided as standard. 250 VA. 250 Vac, 30 Vdc. 5 Amps. |
OPERATION
Four buttons on the front panel enable the batch quantity to be set, and the batch operation to be started, stopped, and reset.FEATURES
Automatic Overrun CompensationOPTIONS
Mass Flow IndicationAPPROVALS
Canadian Standards Association (CSA) CE compliantADDITIONAL INFORMATION
Note: Weatherproof and explosion-proof enclosures are available. Consult factory for dimensions.
Dimensions-Inches to the nearest tenth (millimeters to the nearest whole mm), each independently dimensioned from respective engineering drawings.
| Installation |
| Panel-Mounted-Enclosure |
| Dimensions |
| Copyright © 2008 Natcoparts | Home|Catalogue|Training|Services|News|Careers|Contact us|FAQ|Sitemap |
|