DESCRIPTION

Load Responsive Controller (LRC)


- Provides a one-programmed voltage profile sequence to the grid transformer to produce optimum, or specific, coalescing / mixing for crude oil treating.
- Monitors the Treater Grid performance and protects all components against upset or dangerous conditions such as electrical over load.
- Returns the grid system to normal operation immediately after the occurrence / correction of upset condition
- Quenches the power to terminate high current arcing situations.

Dual Frequency Controller

- The Dual Frequency process improves the performance of an electrostatic dehydration process by creating a high voltage field that promotes aggressive water droplet movement and coalescence. The Dual Frequency process overcomes the problem created by high oil conductivity and low interface tension.
- By using the high frequency transistors to control the voltage levels, the Dual Frequency transformer is capable of combining a high frequency base voltage with a low frequency modulation. The high frequency significantly reduces the voltage decay from the electrodes and sustains the DC voltage field. The low
frequency provides a controlled droplet oscillation and prevents droplet dispersion.
- In addition to the improvements in process performance, the Dual Frequency process typically provides the best performance at lower voltage levels then the typical Dual Polarity or AC processes. This reduces the electrical stress imposed on hangers, bushings, cables, diodes, etc.

Natco NWL Grid Transformers

- 5 – 250 KVA sizes (sized to grid area requirements)
- Primary voltage: 240, 400, 480, 600 VAC, 50 Hz or 60 Hz rating, 1 phase
- Secondary voltage: 12, 16.5, 20, 23, 25 KV DC voltage tapes
- 35% or 100% reactance core windings
- Certification: UL / CSA/ EX Class 1, Div 2
- Transformer is oil filled
- AC to DC High Voltage is diode rectified

ADDITIONAL INFORMATION

*Be sure the white insulating portion of the entrance bushing is extended into the oil phase far enough to remain covered when the grounding float balls in the low (shorted) position.
*Both the (+) and (-) DC electrodes are similarly connected to their polarities on the diode pack.
Contact your nearest Natco Service Centre for Service & Parts & Sizing Toll Free: 1-800-661-6628

Files area
PDF Version PDF Version
Ordering Information

Buy product

Order

Check Part # Description Comments Qty
48126009 EDD 1500 Entrance Bushing (Body)
48126048 High Voltage Cable (78”)
11650065 PFA Tubing 5/16 X 7/16 (78”)
11650067 PFA Tubing 5/8 _ (78”)
48126051 Entrance Bushing (120”)
48126051 Entrance Bushing (120”)
42220000 Transformer Oil (20 Liters)
42221000 1” Entrance Bushing Flex
42221006 1/8” SS Wire Rope
42220002 1/8” Cable Clamp
48126010 1/8” Cable Weight
48400010 3” 150 2” Thick Entrance Bushing Blind
48400020 4” 150 2” Thick Entrance Bushing Blind
48400022 10” X 2” Extension Nipple
48400022 15” X 2” Extension Nipple
48400026 19” X 2” Extension Nipple
48400028 22” X 2” Extension Nipple
42001800 NWL Transformer Lid Clips
48012218 8 ft Teflon Hanger (Standard)
48012220 6 ft Teflon Hanger (Standard)