DESCRIPTION
The NUTECH Model 4065 PMA is two (2) model 40PSR pressure-sensing relays assembled on a manifold with a model 30C1 three-way manual reset relay. The pressure sensors are configured for a high/low pressure sensing application at a single process point. The manual reset relay allows for a local control device that applies the required supply pressure to operate a shutdown valve (SDV). Manual reset requires an operator to physically re-open the system after an abnormal pressure condition has occurred.
Specification
| Operating Pressure Range | 30-10,000 psig(customer specified) |
| Material | 316 SS per ASTM A-276 |
| O-ring | Viton®, Temp. range: -15˚F to + 400˚F (std.) BUNA-N, Temp. range: -65˚F to + 215˚F (opt.) HNBR, Temp. range: -40˚F to +325˚F (opt.) |
| Knob (30C1/30C1P1) | Delrin®(std.) Stainless Steel (opt.) |
| Adjustment cap (40PSR) | Delrin®(std.) Stainless Steel (opt.) |
| Height | 12.0” |
| Width | 10.5” |
| Depth | 6.0” |
| Connections (pilot and relay) | 1/4” FNPT |
| Connections (manifold) | 1/2” FNPT |
| Weight | 17 lbs. |
Features
Pressure sensing relay| Copyright © 2012 Natcoparts | Home|Catalogue|Training|Services|News|Careers|Contact us|FAQ|Glossary|Sitemap |
|