DESCRIPTION
The INVALCO Model 2100 Net Oil Computer is used to determine net oil, net water, BS&W content, and net gas produced in a well test or similar operation.
Specifications
| Enclosure | NEMA 4X fiberglass with clear hinged door. Inner metal door allows easy access to wiring terminals and supports user interface. |
| Memory | Battery backed RAM memory storage of setup and data values for 10 years. |
| Power | 110-220 VAC 50-60 Hz fused at 2 ampre 12 or 24 VDC fuse type Littlefuse @273002 |
| Inputs Counts Temperature Analog Discrete |
3 - dry contact (16Hz maximum frequency) 3 - Pre-amp or photo pulser (10KHz maximum frequency) 3 - pickup coil (10KHz maximum frequency) (Any combination of the count inputs can be configured = 3 meter inputs total) Count Accuracy +/-0.25% of input counts per unit volume. 2 - dual thermistor probe inputs standard (LEMC #5507 probes) -20°F to 150°F standard +/-0.15°F Accuracy 1 - probe for emulsion stream temperature 1 - probe for gas stream temperature averaging. Optional higher temperature ranges available (32°F - 212°F or 60°F - 240°F) 1 - BS&W input scalable for 0-5 VDC, 1-5 VDC 1 - BS&W input scalable 4-20mA (0-100%) 1 - Gas pressure input 1-5 VDC or 4-20mA 3 - Self powered dry contact closure inputs for external monitoring using Modbus Communication. 1 - Self powered dry contact closure input used as system reset integral with reset switch |
| Outputs | 4 - relay NO or NC contacts 10 amp SPDT 3 - relays used for volume pulse output (Net or Gross-tenths of a barrel or cubic foot) 1 - relay for Alarm or Error indication/control 12 or 24 VDC output Serial Communication RS 232 three wire, or RS485 five wire (Modbus RTU communication protocol) |
| User Interface | Screen - 4 line by 20 character vacuum Florissant display. 4 - touch switches used to scroll through screens and change values 1 - toggle switch for reset |
| Buttons | FWD - (forward) - moves through displays in a forward direction. REV - (reverse) - moves through displays in a reverse direction UP - increases values on screens where user interface is required DWN - (down) - decreases values or changes current option on screens where user interface is required. Reset - resets totals. Optional external reset with dry contact using terminal block input where Reset switch is terminated also. |
FEATURES&BENEFITS
- 3 Meter Inputs| Copyright © 2008 Natcoparts | Home|Catalogue|Training|Services|News|Careers|Contact us|FAQ|Sitemap |
|